BASIC SET-UP PROCEDURES
Aqua Phase
, A Division Mid-State Stainless Inc. ● 330 W. Benson Ave. ● PO Box 228 ● Grantsburg, WI 54840 ● USA
800-208-9274 ● 715-463-5851 ● FAX: 715-463-5853 ● Email: [email protected] ● WEB: www.aqua-phase.com
If Aqua Phase has been transported during freezing weather, allow the Aqua Phase to warm for
4-6 hours before running.
1.
Read all Aqua Phase instructions and operations material
2.
Remove Aqua Phase from pallet
3.
Move Aqua Phase to location of operation. Ensure that Aqua Phase is level
4.
Remove items packed inside the Wash Chamber for shipping (hoses, optional racks, trays,
and
chemical solutions will often be packed inside the Wash Chamber).
5.
Connect the Fill Hose using supplied hose.
•
DO NOT USE A GARDEN HOSE.
•
Only use hoses rated for 150° F or higher for both fill and drain connections.
6.
Connect the drain hose.
•
The
drain end of the hose MUST BE HIGHER than the drain hose connection on
the
washer.
See Fill and Drain Line page for information.
•
Drain hose must be securely fastened to the drain.
7.
Once the Fill and Drain connections are secure, slowly turn on your hot water supply and
inspect for
loose connections.
8.
For standard 120-volt operation, connect Aqua Phase to a standard 20 AMP electrical service
•
Press the reset button located on the Ground Fault Circuit Interrupter (GFCI) in the
power cord.
•
DO NOT
use a power extension cord between the wall outlet and the Aqua Phase
9.
With Special Ordered
240-volt configuration, the end user must make the final
connections and
provide the
appropriate
cord plug
with
Ground Fault Circuit Interrupter
(GFCI) reset button.
•
Due to the variety of receptacle and connection types as well as local codes and
regulations, all electrical connections should be performed by a qualified electrician in
accordance with local codes and regulations.
(Continued next page)
Electrical line inlet
Electrical connection J-box
inside Mechanical Cabinet
Summary of Contents for AQ-F250