Audio Alarm (Right)
Silence detected on Right Output Channel
Minor
Left Input silence Detect
Silence detected on Left Input Channel
Minor
Right Input Silence Detect
Silence detect on Right Input Channel
Minor
Dial out Connection
An ISDN dial has been made to another unit
– shows desti-
nation number
Event
Incoming Call Connection
An incoming ISDN connection has been detected
Event
Codec Configuration
The configuration of the codec has changed
Event
Unit Mode Change
The codec has switched to a different network
Event
Rx IP Connected
An RX IP Connection is established
Event
Tx IP Connected
A Tx IP Connection is established - shows destination IP ad-
dress
Event
Dropped packet Count
Dropped packets are detected
Alarm
Configuration Mismatch
Mismatch in incoming RTP packets headers to expected con-
figuration
Alarm
Loss of Connection
Loss of physical IP connection
Alarm
Keep Alive Packet Detect
Misconfigured Packet Count
Fan 1 Stall
Fan 2 Stall
PSU 1 Fail
PSU 2 Fail
A keep-alive packet has been detected across the IP connec-
tion
An incremental counter which accumulates the number of
misconfigured packets
If fan 1 stalls then this alarm will be raised
If fan 2 stalls then this alarm will be raised
– this will only ap-
pear if a second PSU is fitted
PSU 1 Failure
– will only appear if second PSU is fitted
PSU 2 Failure
– will only appear if second PSU is fitted
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Event = An event which can be used for information and is not an alarm condition
Alarm = An alarm condition which is logged but not flagged on the NMS
Major = A major alarm condition
Minor = A warning condition
6.3.10.
The User Management
Tool Bar
Users button
The User Management
window allows you to
add or delete user ac-
counts.
Click Add New User
to confirm