This diagnosis is activated when the correction
constantly arrives -25%.
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSTIC TOOL: STATUSES
Lambda probe: Start-up_Lean_Rich_Fault due to rich titre_Fault due to lean air-fuel mixture
•
If the probe connector is disconnected (voltage almost equal to zero) it switches to the state
of Fault due to lean air-fuel mixture
Lambda check: Open loop/Closed loop/Rich in closed loop/Lean in closed loop/enriched
•
Closed loop indicates that the control unit is using the lambda probe signal to keep the
combustion is close as possible to the stoichiometric value.
DIAGNOSTIC TOOL: ACTIVATIONS
Lambda probe heater
•
The injection relay (No. 33 in the electrical circuit diagram, placed under the saddle next to
the battery positive, CHECK, however, the identification of the relay with the colour of the
cables) is energised and the heating circuit is closed to ground 5 times (pin 3 of the Lambda
probe connector). Electrical continuity is required in the wiring for the relay to activate cor-
rectly: no errors are generated in case of no activation.
DIAGNOSTIC TOOL: ELECTRICAL ERRORS
P0130 Front bank lambda probe
Electrical diagnosis:
•
Short circuit to positive.
Error cause:
•
Excessive voltage detected (battery voltage) at PIN 10 and 22 of the ENGINE connector.
Caution: the "lambda probe" parameter is not the actual read value but a recovery value is
displayed.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light.
Troubleshooting:
•
Short-circuit to positive: with key ON, disconnect the sensor connector and measure the
voltage at PIN 1, wiring harness side (grey cable): if the voltage (5 or 12 V) is present, restore
the wiring harness, if the voltage is absent replace the lambda probe
P0135 Rear bank lambda probe heating
Electrical diagnosis:
•
short circuit to positive/ open circuit, short circuit to negative
Error cause
Tuono V4 1100 Factory
Electrical system
ELE SYS - 199
Summary of Contents for 2Q000504
Page 1: ...SERVICE STATION MANUAL 2Q000504 Tuono V4 1100 Factory ...
Page 4: ......
Page 6: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 12: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 63: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 103: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 270: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 299: ...INDEX OF TOPICS ENGINE ENG ...
Page 415: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 425: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 463: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 508: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 548: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 561: ...INDEX OF TOPICS BODYWORK BODYW ...