Short-circuit to positive: disconnect the coil connector, turn the key to ON, activate the coil
with the diagnostic tool and check the voltage at PIN 28 of the connector: if there is voltage,
restore the wiring harness, if the voltage is 0, replace the coil.
•
If open circuit, short circuit to negative: check the electrical characteristics of the coil: if not
ok, replace the coil; if ok, perform the check procedure for the coil connector and for the
Marelli control unit connector; if not ok restore; if everything is ok, check the continuity of the
cable between the two ends of the cable: if there is no continuity, restore the wiring harness;
if there is continuity, with key ON, check the cable ground insulation (from the coil connector
or control unit connector); if not ok, restore the wiring harness.
P0352 Coil 2
Electrical diagnosis:
•
Short circuit to positive / short circuit to negative, open circuit.
Error cause:
•
Short-circuit to positive: an excessive voltage was detected at PIN 27 of the ENGINE con-
nector. If open circuit, short circuit to negative: a voltage equal to zero was detected at PIN
27 of the ENGINE connector.
Troubleshooting:
•
Short-circuit to positive: disconnect the coil connector, turn the key to ON, activate the coil
with the diagnostic tool and check the voltage at PIN 27 of the connector: if there is voltage,
restore the wiring harness, if the voltage is 0, replace the coil.
•
If open circuit, short circuit to negative: check the electrical characteristics of the coil: if not
ok, replace the coil; if ok, perform the check procedure for the coil connector and for the
Marelli control unit connector; if not ok restore; if everything is ok, check the continuity of the
cable between the two ends of the cable: if there is no continuity, restore the wiring harness;
if there is continuity, with key ON, check the cable ground insulation (from the coil connector
or control unit connector); if not ok, restore the wiring harness.
P0353 Coil 3
Electrical diagnosis:
•
Short circuit to positive / short circuit to negative, open circuit.
Error cause
•
Short-circuit to positive: an excessive voltage was detected at PIN 2 of the ENGINE con-
nector. If open circuit, short circuit to negative: a voltage equal to zero was detected at PIN
2 of the ENGINE connector.
Troubleshooting
Electrical system
Tuono V4 1100 Factory
ELE SYS - 210
Summary of Contents for 2Q000504
Page 1: ...SERVICE STATION MANUAL 2Q000504 Tuono V4 1100 Factory ...
Page 4: ......
Page 6: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 12: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 63: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 103: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 270: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 299: ...INDEX OF TOPICS ENGINE ENG ...
Page 415: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 425: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 463: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 508: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 548: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 561: ...INDEX OF TOPICS BODYWORK BODYW ...