Installation
GT3000
28
IMGT30017EN
3A.3.2
Power cables and power fuses
Select power cables and power fuses according to the following tables. Use copper input power cables and motor cables with a 600-690 VAC
rating. Use cable with a 1000 VDC rating for dynamic brake wiring.
Table 3A.3.2 Power Cable and Fuses Sizing ( 380-460 VAC; 510-650 V
DC
)
F=Three-phase supply voltage 380V, 415V, 440V, 460V, 480V / Y=510-650V
DC
±10%
Model
Supply Main Fuses
Fuses type)
Cables section
Terminals
Max torque
Max Line Short
Circuit Current
[A]
(UL)
AWG
mm
2
Nm
lbf ft
kA
SVGT0P3F
AC/DC
5x3/2
FWP-15A
14
2,5
10 (AWG max)
0,5
4.425
5
SVGT0P4F
AC/DC
10x3/2
FWP-15A
14
2,5
10 (AWG max)
0,5
4.425
5
SVGT0P6F
AC/DC
15x2
FWP-20A
14
2,5
10 (AWG max)
0,5
4.425
5
SVGT008F
AC
15x3
FWP-20A
14
2,5
10 (AWG max)
0,5
4.425
5
SVGT008F
DC
20x2
FWP-25A
14
2,5
10 (AWG max)
0,5
4.425
5
SVGT011F
AC
20x3
FWH-40A
12
4
10 (AWG max)
0,5
4.425
5
SVGT011F
DC
25x2
FWP-40A
12
4
10 (AWG max)
0,5
0.37
5
SVGT015F
AC
30x3
FWH-45A
10
6
10 (AWG max)
0,5
0.37
5
SVGT015F
DC
30x2
FWP-45A
10
6
10 (AWG max)
0,5
0.37
5
SVGT018F
AC
35x3
FWH-45A
10
6
10 (AWG max)
0,5
0.37
5
SVGT018F
DC
40x2
FWP-50A
10
6
10 (AWG max)
0,5
0.37
5
SVGT022F
AC
50x3
FWH-60A
8
10
6 (AWG max)
1,2
0.88
5
SVGT022F
DC
50x2
FWP-60A
8
10
6 (AWG max)
1,2
0.88
5
SVGT028F
AC
50x3
FWH-70A
8
10
6 (AWG max)
1,2
0.88
5
SVGT028F
DC
60x2
FWP-90A
8
10
6 (AWG max)
1,2
0.88
5
SVGT030F
AC
50x3
FWH-70A
8
10
6 (AWG max)
1,2
0.88
5
SVGT030F
DC
60x2
FWP-90A
8
10
6 (AWG max)
1,2
0.88
5
SVGT036F
AC
60x3
FWH-100A
6
16
4(AWG max)
2
1.47
5
SVGT036F
DC
80x2
FWP-125A
6
16
4(AWG max)
2
1.47
5
SVGT045F
AC
70x3
FWH-150A
3
25
35
2,5
1.84
5
SVGT045Y
DC
90x2
FWP-125A
3
25
35
2,5
1.84
5
SVGT053F
AC
90x3
FWH-200A
2
35
35
2,5
1.84
10
SVGT053Y
DC
125x2
FWP-175A
2
25
35
2,5
1.84
10
SVGT066F
AC
100x3
FWH-200A
2
35
35
2,5
1.84
10
SVGT066Y
DC
150x2
FWP-175A
2
35
35
2,5
1.84
10
Input
Output
SVGT086F
AC
125x3
FWH-225A
2/0
70
M6
M8
10
7.37
10
SVGT086Y
DC
175x2
FWP-225A
2/0
70
M6
M8
10
7.37
10
SVGT108F
AC
175x3
FWH-225A
3/0
95,0
M6
M8
10
7.37
10
SVGT108Y
DC
200x2
FWP-225A
4/0
95,0
M8
M8
10
7.37
10
SVGT125F
AC
200x3
FWH-300A
4/0
95
M8
M8
10
7.37
10
SVGT125Y
DC
300x2
FWP-400A
250
95
M8
M8
10
7.37
10
SVGT150F
AC
250x3
FWH-300A
250
120
M8
M8
10
7.37
10
SVGT150Y
DC
350x2
FWP-400A
2/0x2P
120
M8
M8
10
7.37
10
SVGT166F
AC
250x3
FWH-300A
250
120
M8
M8
10
7.37
10
SVGT166Y
DC
350x2
FWP-400A
2/0x2P
120
M8
M8
10
7.37
10
1
Standard gG fuses with current rating: 1.3 times GT3000 rated current for AC power supply can be used on CE market.
Summary of Contents for GT3000
Page 1: ...GT3000 Hardware Software Manual www answerdrives com ...
Page 2: ......
Page 4: ......
Page 8: ...Table Of Contents GT3000 iv IMGT30017EN ...
Page 12: ...General Safety Precautions viii IMGT30017EN ...
Page 25: ...GT3000 Technical Data IMGT30017EN 13 Frames IV V VIN SVGT045 166 IP20 ...
Page 26: ...Technical Data GT3000 14 IMGT30017EN Frames IV V VIN SVGT045 166 IP54 ...
Page 28: ...Technical Data GT3000 16 IMGT30017EN Frames VII VIII IP00 SVGT200 521K SVGT200 470F ...
Page 29: ...GT3000 Technical Data IMGT30017EN 17 F series Frames 2xVII 2xVIII Parallel IP00 SVGT520 940M ...
Page 30: ...Technical Data GT3000 18 IMGT30017EN K series Frames 2xVII 2xVIII Parallel IP00 SVGT580 960K ...
Page 36: ...Installation GT3000 24 IMGT30017EN 3A 2 1 4 Frames VII VIII Installatiion ...
Page 58: ...GT3000 Installation 46 IMGT30004EN ...
Page 107: ...GT3000 Terminal Boards and Power Schematics IMGT30017EN 95 ...
Page 110: ...Terminal Boards and Power Schematics GT3000 98 IMGT30017EN ...