Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
230V/1N.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Open the hatch (B).
3 - Undo the screws (C) to remove the electrical
equipment box (D).
ELECTRICAL CONNECTION
4 - Undo the screws (E) to remove the lid (F).
5 - Connect the circuit-breaker (A) to the terminal
board (G) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
6 - Tighten the cable gland (H).
Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.
7 - Fit the lid (F) and secure it with the screws (E).
8 - Fit the electrical equipment box (D) and secure
it with the screws (C).
9 - Close the door (B) when the operation is complete.