Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
the connection to the proper standards,
and must comply with all the relevant regu-
lations and legislation. Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks.
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a flue with
natural draught
1 - Connect the appliance's
exhaust outlet to the flue
(A) using a line comply-
ing with the dimensions
shown in the diagram.
Connecting to a fan extractor hood
1 - Position the appliance underneath the hood (B)
and connect a line of the dimensions shown in
the diagram to the appliance's exhaust outlet.
Important
The fan of the extraction system must
switch on automatically when the gas sup-
ply tap is turned on.
GAS CONNECTION
CONNECTION OF FUME EXHAUST VENT