Pressure filter for tank mixture agitators:
1)
Filter body
2)
Cartridge
3)
ORing seal
4)
Bottom cover
5)
Drain tap
This filter protects the high pressure agitators nozzles inside the main tank.
To check/clean the pressure filter cartridge:
Unscrew the bottom cover (4)
Remove the cartridge (2)
The pressure filter has a drain tap: during the flushing operations of the chemicals circuit it is possible to
clean the filter cartridge opening the tap. Nevertheless, it is mandatory to periodically open the filter and
check the cartridge.
Periodically open the filter and clean the cartridge.
Take care not to damage the ORing (3).
Do not waste chemicals residues in the environment.
During flushing operations of chemicals circuit, when using drain taps of pressure filters, make
them discharge into suitable containers by flexible hoses.