74/166
Main suction filter:
1)
Filter body
2)
Cartridge
3)
ORing seal
4)
Bottom cover
5)
Locking nut
6)
Safety valve
To check/clean the suction filter cartridge:
Remove the safety valve (6)
Unscrew the locking nut (5)
Remove the bottom cover (4)
Remove the cartridge (2)
Open the filter and check the cartridge before every spray operation.
Take care not to damage the ORing (2).
Periodically check the Oring and replace if damaged.
A damaged ORing can make the pump suck air and therefore generate instability in pressure
and spray quality.