7.8
AIR FILTER
The machine, especially when used in dusty conditions, requires high care in cleaning the air filter.
It is mandatory to clean the filter at least every 10 hours of work ; frequency of cleaning depends on
work conditions.
All service operations MUST be done with engine stopped.
Wait some minutes for cooling of components.
Open the engine covers to approach the filter.
1)
Engine air filter
2)
Electric sensor clogging indicator
To clean the filter:
1)
Air filter cap
2)
Primary cartridge
3)
Secondary cartridge
4)
Drain valve
Remove air filter cap.
Remove the filter cartridges, primary and secondary.
Carefully clean the filter elements with compressed air.
Also clean filter body parts and drain valve (4).