Appendix G - External Serial Controllers
287
Enova Digital Media Switchers - Hardware Reference Manual
Baud Rate - 115200
Data Bits - 8
Parity - None
Stop Bits - 1
Flow Control - None
NOTE:
For terminal emulation via the serial port, use the terminal in NetLinx Studio (see below) or another terminal emulation
program.
Serial Communication Settings
If you are controlling the system with a serial controller, use serial communication software and make sure the baud rate is
set correctly for the system.
Supported baud rates are 115200 (default), 19200, 38400, and 57600. The settings on the PC serial communication
software and the enclosure
must
correspond to each other.
If a change is required to make them match, changing the PC’s settings is preferable. If you decide to change the
enclosure’s settings instead, use NetLinx Studio.
Terminal Emulation via NetLinx Studio
For terminal emulation, use the terminal in NetLinx Studio (Tools/Terminal Session) or another terminal emulation program.
When power is applied to the enclosure, the terminal will display a one-line splash screen followed by "
Ready
." The system
is ready to accept commands (FIG. 178):
FIG. 178
Power-up splash screen in NetLinx Studio Terminal
CONTROL (Serial) port
Cable to serial control device / system