![background image](http://html1.mh-extra.com/html/amx/dgx-aie/dgx-aie_hardware-reference-manual_2939028274.webp)
Appendix F - DGX Configuration Software
274
Enova Digital Media Switchers - Hardware Reference Manual
4.
Click
Refresh EDID
. A short description of the destination device displays to the left of the drop-down list along with
the Manufacturer ID and Product ID (e.g., DELL 2408WFP; DEL; a02a). The Scaler Override view is populated with the
EDID timings from the detected device.
5.
Complete one of the following options (each option includes a step for saving the EDID). Note that options A, B, and
C assume that the previous instructions for reading an EDID have been completed and the DGX Configuration
Software is open to the Scaler Override view:
a.
To set the EDID timings that were read from the device that was detected in the previous step, see the next
page.
b.
To set a standard preset, which applies standard timing, see page 275.
c.
To set a custom resolution with the option of applying advanced detailed timing settings, see page 276.
NOTE:
When a number of outputs are connected to destination devices of the same type, the Get Current Timing button can be
used to retrieve the settings.
(A) Setting an EDID Timing That Was Read From The Detected Device
1.
Under Resolution Source, click
EDID
.
2.
Under EDID from Detected Device – From the Available Display Modes drop-down list, select the desired resolution
(only resolutions supported by the detected device are included).
3.
In the device tree on the left, select an output to send the resolution information to that output. Multiple outputs may
be selected.
4.
Click
Apply
to transmit the selected information to the output(s). This action is temporary until settings are stored on
the connector(s) in Step 6. Otherwise, the settings last only until power is cycled. The display re-syncs with the input(s).
5.
Verify that the display is satisfactory before proceeding.
6.
Click
Save
to store the currently displayed settings to the connector(s) and persist them in memory. If the settings
have been changed since clicking Apply, the newest settings will be saved.
FIG. 162
Destination device description, Manufacturer ID, and Product ID
FIG. 163
Scaler Override view with EDID selected
Device tree with Outputs