Installation and Setup
57
Enova Digital Media Switchers - Hardware Reference Manual
System Configuration Interface Setup
System Requirements
Minimum web browser requirements – Google Chrome v30, Internet Explorer v10, Firefox v24, Safari v6.0, Opera v24, or
other browser with substantial support for HTML5 features
NOTE:
User experience may differ due to browser support for HTML5.
Setting up the system to use AMX’s System Configuration interface requires completing the following three items. Detailed
instructions for each item are given.
Determine the integrated Master’s IP address via the front Control Panel
Open a web browser on the PC. Note that the PC (or tablet) must be on the same LAN that the enclosure is
connected to via the LAN 100/1000 port.
Open the System Configuration interface
NOTE:
Place source and destination devices within view until the test switch confirms correct routing behavior. Any
applicable modules/wallplates should be correctly installed and power must be applied to both the enclosure and
source and destination devices.
The steps below assume that the DGX is powered on and connected to the LAN via the LAN 100/1000 port (FIG. 25).
Logging On To the System Configuration Interface and Executing a Test Switch
NOTE:
The System Configuration interface can also be launched via NetLinx Studio (see page 209).
1.
Determine the integrated Master’s IP address:
a.
On the front Control Panel, locate
Setup Options
by scrolling with the Control Dial.
b.
Press the
Select
key.
c.
Locate
IP Address
by scrolling with the Control Dial.
d.
Press the Select key to display the IP Address.
e.
Record the IP address for use in Step 3.
2.
On a PC or tablet, open a web browser that supports HTML5.
3.
In the web browser’s address bar, enter the Enova DGX’s IP address and press Enter. The System Configuration
interface’s Home page appears in the browser.
IMPORTANT:
The default Username for the interface is "administrator" and the default Password is "password". After initial
setup, defaults should be changed to ensure system security.
4.
From the main menu bar at the top of the screen, select Switcher>Switching. The Switching page appears.
5.
Disconnect the factory default switch (Input 1 routed to all Outputs):
a.
Click Input 1.
b.
Under outputs, select
Deselect All
.
c.
Click
Take
.
6.
Make sure the first two source devices and the first two destination devices are connected to the first two input and
output connectors (for specific board connector information and specifications, see the board chapter).
7.
Route Input 1 to Output 2 (click Input 1, then Output 2, then click the
Take
button).
8.
To verify the switch, click Input 1 again. Both the Input 1 and Output 2 buttons will turn blue and both selections will
appear in the Selected pane on the right.
9.
Disconnect the test switch (click Output 2 and click Take) and finish the installation.
For System Configuration interface tips, see page 201.
NOTE:
For instructions on executing a test switch via BCS Commands, see the "BCS (Basic Control Structure) Protocol
Programming Guide" at www.amx.com.
Additional Setup Options
Audio Control and Signal Processing (see the following page)
Establish serial communication with a PC via the Program port (see page 58)
Attaching an AxLink device (see page 59)
Using the ID Pushbutton (see page 60)
Enable Program Run Disable (PRD) Mode (see page 61)