background image

Excel Light Switch

and Timer

24 hour and 7 day
Cat XL770T & XL770TH (horizontal)

The Cat XL770T & XL770TH timer switch simply replaces a normal
light switch and provides automatic switching of incandescent,
fluorescent, halogen or dichroic lights as well as fan motors.
A multitude of switching options can be carried out over a 
7 day period.

Features

  Simply replaces a standard light switch.

  Operates as a normal light switch - or can be quickly switched

 

to ‘automatic’ for timer control.

   If required, several may be used in key rooms of the house to 

 

simulate a ‘lived in’ appearence.

  Has ‘random’ setting to simulate ‘lived in’ situations when the

 

home is vacant.

  Accurate 24 hour digital clock.

  Backlight turns on with first button press.

Specification (at 25ºC)

Supply voltage: 

230-240V a.c. 50Hz

Setting options: 

Up to 8 on/off times per day

Max and min load: 

See table below

Operating temperature 

0 to 50ºC

Load Type

Min Load

Max Load

Incandescent & 

240V Linear Halogen

10W

  

500W

240V GU10 Halogen Downlights

Not suitable*

Compact Fluorescent

150W**

500W

Linear Fluorescent

(Electronic Ballast)

150W**

500W

Linear Fluorescent

(Magnetic Ballast with Power Factor Correction)

40W***

500W***

Linear Fluorescent

(Magnetic balast without Power Factor Correction)

100VA****

500VA****

Low Voltage Halogen

(Electronic Transformer)

10W

500W

Low Voltage Halogen

(Magnetic Transformer)

10W

400W

 Fan Motor

10VA

500VA

*    GU10 240V Halogen Downlights can damage the XL770T when 
 

they fail, and are therefore not recommended for use with this product.

**   A minimum load of 10W can be achieved if a resistive load is 

connected in parellel with the fluorescent load. This can be, for 
example a resistor or incandescent lamp rated at least 10W.

***   Power factor correction capacitors must be placed on the 

line side of the XL770T. If this is not possible then they should 
either be removed, or a 36W magnetic ballast should be 
connected in parallel with the fluorescent load, to prevent 
damage to the XL770T.

****   Refer to the following table for VA ratings when power factor 

correction is not used:

PRODUCT

INFORMATION

Tube Size

Effective load

1 x 15W

85VA

1 x 20W

85VA

1 x 30W

85VA

1 x 40W

105VA

Tube Size

Effective load

1 x 65W

170VA

1 x 80W

210VA

2 x 20W

185VA

2 x 40W

210VA

Note:

1. This product cannot be used for two-way switching.
2. This product cannot be used with a light dimmer.

Installation

The XL770T & XL770TH is installed in the same way as a normal 

light switch. A wiring diagram is shown on page 4, (Fig 3).

12:30

8

X

Sun

X

Mon

X

Tue

X

Wed

X

Thur

X

Fri

X

Sat

ON

OFF

ST

Random

Operation

Flashing timer.
Programs may be
altered when timer
is in this mode.
Shows whether
program is enabled
or disabled.
Summertime
switches to daylight
saving.

ON and OFF
for timer settings

Flashing number

represents

program(1 to 8)

Time & on/off

settings.

Fig 2.

1

MAN

AUTO

Set  Day  Hrs  Min  Man

We

OFF

12:30

Reset.

Switch operates

only in manual

mode.

Auto: switches on/off
in timer mode.
Man: manual operation
enables switch,
at left, to function.

Example: Cat XL770T

Fig 1.

N.B.

 If connected incorrectly or if load exceeds the above values, 

an internal fuse will rupture, rendering the unit inoperable. 

WHAT TO DO IF THE DISPLAY IS BLANK

When this unit is not connected to power for a long period 
of  time,  the  back-up  battery  will  run  down  and  the  display 
will go blank. When power is re-connected, wait for about 20 
minutes for the internal battery to charge up before attempting 
to program the unit. After this time, the display may still not 
return to normal. If this should happen, press the reset button, 
see Fig 1, using a small insulated object.

This procedure will erase the memory contents of the unit.

Summary of Contents for XL770T

Page 1: ...pacitors must be placed on the line side of the XL770T If this is not possible then they should either be removed or a 36W magnetic ballast should be connected in parallel with the fluorescent load to prevent damage to the XL770T Refer to the following table for VA ratings when power factor correction is not used PRODUCT INFORMATION Tube Size Effective load 1 x 15W 85VA 1 x 20W 85VA 1 x 30W 85VA 1 ...

Page 2: ...e timer will come on during weekdays only not weekends Pressing Day once gives the following display This means that the timer is to operate during weekends only If Day is pressed again all the days of the week will be displayed meaning the timer is to operate everyday The next press will highlight Su then Mo then Tu etc Each progressive press will highlight another single day the timer to operate...

Page 3: ...ode press the Set key until the clock face icon appears as a flashing sign at the top right of the display Continue to press Set and the display will show ON OFF times and step from program 1 to 8 Pressing Set further the timer will then revert to clock mode Daylight saving time adjustment In clock mode press and hold the Min key for 3 seconds ST will appear on the display Press Hrs key once to dec...

Page 4: ...IMER OPERATION OFF OFF ALWAYS ON ON OFF ALWAYS OFF ON ON ALWAYS OFF Note Back up battery The back up battery ensures that programmed information is not lost in the event of a power failure The battery has a life of approximately 6 years After this 6 year period the back up facility may cease to function HPM Cat XL770T XL770TH are warranted as here and after appears against faulty material and or w...

Reviews: