The 4Gb HBA of Choice 

In Oracle Environments 

QLogic vs. Emulex 4Gb Fibre Channel HBA 
Performance Benchmarking with Oracle 
Workloads 

 

Executive Summary  

 
Today’s mission-critical Online Transaction Processing (OLTP), Online Analytical Processing 
(OLAP) and Web applications demand the highest levels of performance from their database 
servers and storage infrastructure.  To satisfy this demand, organizations are making the transition 
to 4Gb Fibre Channel SANs, and IT decision makers are under pressure to select the right 
components in order to ensure a cost-effective and scalable solution.  

 

A critical element of overall SAN performance is the selection and deployment of a Host Bus 
Adapter (HBA) with the right architecture.  With the introduction of multi-processor CPUs coupled 
with virtualization technologies, high performance database solutions need to be complemented 
with high performance and scalable IO connectivity. A wrong choice can result in management 
complexity and limit an organization’s overall business agility to meet continually evolving business 
needs. 
 
To help IT decision makers make the best, most informed HBA choice, QLogic has performed a 
series of head-to-head performance benchmarks showing the I/O performance and scalability 
advantages of the QLogic SANblade™ Pro 2400 series HBAs over Emulex® LightPulse® HBAs in 
a variety of real-world OLTP, OLAP and Web scenarios using SAN-attached Oracle databases. 
  
QLogic compared the overall performance of the 4Gb HBAs when attached to industry leading 
storage arrays and solid state drives to emulate a real-world SAN with maximum throughput 
workloads.  Our tests highlight the advantage delivered by QLogic’s SAN Pro architecture in 
Oracle environments. 

 

 

Key Findings 
 

For demanding enterprise database applications, choosing QLogic 4Gb FC HBAs provides:  

 

33% Higher Performance 

 

Using best-in-class Oracle™ and EMC™ components in OLTP, Web and 
OLAP workloads indicative of real-world storage configurations, QLogic HBAs 
demonstrated 33% better throughput than Emulex HBAs. 

 

28% Superior Scalability

 

 

In high-performance database applications, emulated with Oracle workloads, 
QLogic’s SANblade 2400 series dual port HBAs deliver 28% higher IOPs 
compared to the Emulex’s 11000 series HBAs.

 

Summary of Contents for SANbox 5600 Series

Page 1: ...ility to meet continually evolving business needs To help IT decision makers make the best most informed HBA choice QLogic has performed a series of head to head performance benchmarks showing the I O...

Page 2: ...lly when used in a database application were one of the following The ability to handle multiple data requests and the volume of data or throughput as measured in megabytes per second MBps with an inc...

Page 3: ...st configuration setup Figure 1 Test Setup All tests were run using the HBA default settings from both companies Test Procedure The test procedure using an enterprise storage array was as follows 1 A...

Page 4: ...than Emulex The performance was measured against an increasing load on the HBAs determined by number of outstanding Input Output I Os requests All tests used a standard block size of 1 megabyte Note...

Page 5: ...was visible through its respective port on the HBA Figure 2 Test Setup to Measure Scalability The tests were performed using the latest hardware software and drivers that were commercially available a...

Page 6: ...in a production setting Performance of the QLogic and Emulex HBAs was measured using a critical parameter the rate at which I O requests are serviced IOPs Higher IOP values denote greater throughput...

Page 7: ...ior Scalability QLogic s dual port HBAs scale better in OLTP tests with higher work loads and deliver 28 higher IOPs compared to Emulex HBAs The key to the increased performance advantage can be attri...

Page 8: ...e needs of enterprise SANs Investment protection Future proof SAN infrastructure in the data center with higher performance 4Gb QLogic HBAs Higher performance and scalability backward and forward comp...

Page 9: ...Dell Power Edge 6850 FC HBA Configuration QLogic and Emulex FC HBA QLogic Driver STOR miniport QLogic Driver Version 9 1 2 16 Emulex Driver STOR miniport Emulex Driver Version 1 11a3 External Storage...

Page 10: ...drivers are available at http www emulex com ts downloads stor storport html Disclaimer Reasonable efforts have been made to ensure the validity and accuracy of these comparative performance tests QL...

Reviews: