www.amico.com
37
Installation: Adjustments
Vertical Adjustment
Vertical stop screws can be adjusted to avoid collision
with a low ceiling or with other spring arms in operation
above or below it.
1. Locate the vertical adjustment screws; the fixed end
of the spring arm has four vertical adjustment screws.
2. OASYS spring arms contain a built-in 45° degree stop,
which is enabled by unscrewing all four vertical stop
screws with a 5 mm Allen key.
3. For angles between 0° and 30°, adjust the spring arm
away from the stops, unscrew all of the vertical stop
screws and replace them in the correct positions.
4. Replace the covers.
Installation: The Base Cap
1. Center the base cap at the bottom of the central axis over the retaining lock nut.
2. Align the locking tooth into one of the notches in the nut at the bottom of the central axis.
3. Press the cover up until it bottoms against the nut. Lightly tighten the three set screws equally, until the cover is
snug and secure.
Locking Tooth
Central Axis
Base Cap
Vertical Stop Screw
Vertical Stop Screw