37
5800 SE 78th St. Ocala, FL 34472
Modular HURRiCHiLL Installation & Operations Manual
P: (800) 327-3015
Customizing the Cycles and Technical Settings - Continued
Setting
Description
Icon
Sanitize
Settings for: Length of Cycle, Auto Sanitation and Auto
Sanitation Time.
PC
Select the type of PC connection you use and see detailed
info on the network settings.
Home
Takes you back to the home screen
Settings
Takes you to Technical Settings Screen - Optional Cycles,
Temperature Probe(s) Setup, Contacts Setup, Features,
Alarms, Brightness and Sound settings
Optional Cycles - Choose additional non standard cycles
Probe Settings - Adjust probe temperatures and offsets
Contacts Settings - Settings for contact sensors in the unit.
Features - Technical features to be used by technician
Alarm Settings - Settings for all alarms
Temperature Probe Calibration
1. Determine the temperature offset for the probe you are calibrating. To do so, insert the food probe in an 80% ice
20% water bath and stir for a minute. Record the temperature of the probe as displayed on the touchscreen. The
difference between 32 and the temperature reading is the temperature offset.
2. For example, temperature probe reading is 38˚F. The temperature offset is -6 (32-38 = -6)
3. Calibrate the probe. To do so go to Settings (7055 Login) > Settings > Temperature Probes Setup. Set the offset
calculated above for the desired temperature probe. Press Done button to go to the home screen.