20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Networked Indexer/Driver User Manual
C
ONFIGURATION
D
ATA
F
ORMAT
61
CFG_Word_1 Format (continued)
† Active Low: The Networked Driver will report that the input is active when it is not conducting current.
Active High: The Networked Driver will report that the input is active when it is conducting current.
Table R6.4 Configuration Word 1 Bits
...Set These Bits To
To Make These Settings...
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Input 1
Active Low
†
0
Active High
†
1
Input 2
Active Low
†
0
Active High
†
1
Input 3
Active Low
†
0
Active High
†
1
DC_Sync
Disabled
0
Enabled
1
OUT1_State_
at_Conn_Lost
Output Off
0
Output Conducting
1
OUT1_Action_
On_Conn_Lost
Retain Last Value
0
Use state of bit 12
1
OUT1_Function
Fault Output
0
GP Output
1
Resulting Bit Pattern:
0
0 0 0 0 0
0 0 0
Hexadecimal Digits for
CoE Configuration Setting: