Cleaning, maintenance and repairs
13.9.1.1 Determining the actual spray rate while stationary via the individual nozzle output
Also set the spray rate of the control terminal / AMASPRAY
+
in man-
ual mode via the spray pressure according to the spray table.
Collect the nozzle output from at least 3 different spraying nozzles. To
do this, check one spraying nozzle on both the left and right-hand
boom, as well as one on the sprayer boom centre section.
Then calculate the actual spray rate [l/ha] from the collected nozzle
output [l/min] or read the appropriate value directly from the spray
table.
1. Determine the precise spray rate [l/ha] required for the crop pro-
tection measure. Refer to the section "Calculating the filling and
re-fill quantity", Seite 142.
2. Determine the required spray pressure.
3. Fill the spray liquid tank with water.
4. Switch on the agitator (normally at stirring stage "2").
5. Manually set the required spray pressure.
6. Switch on spraying and check that all nozzles are functioning
perfectly.
7. Switch off spraying.
8. Determine the individual nozzle output [l/min] from multiple noz-
zles, e.g. using a stopwatch,a dosing cylinder and a measuring
container.
9. Calculate the average individual nozzle output [l/min].
Example:
Nozzle size:
'05'
Intended operational speed:
8.0 km/h
Required spray pressure:
3.2 bar
Nozzle output on the left-hand boom:
1.9 l/min
Nozzle output in the middle section:
2.0 l/min
Nozzle output on the right-hand boom: 2.1 l/min
Calculated average value:
2.0 l/min
196
UF BAG0012.11 04.19
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......