Product description
4.12
Maximum permissible application rate
The permissible application rate of the implement is limited by the
minimum required agitator capacity.
The agitator capacity per minute should be 5% of the hopper volume.
This is particularly applicable for active substances that are hard to
keep in suspension.
With active substances that are dissolved, the agitator capacity can
be reduced.
Determining the permissible application rate depending on the agitator capacity
Calculation formula for the application rate in l/min:
(Agitator capacity per minute = 5% of the tank volume)
Permissible application rate
=
Pump capacity
- 0.05 x nominal tank volume
[l/min]
[l/min]
[l]
(see technical data)
Conversion of the application rate in l/ha:
1. Determine the application rate per nozzle (divide the permissible
application rate by the number of nozzles).
2. Read the application rate per hectare depending on the speed
from the spray table (See page
210
).
Example:
UF 1501, pump BP 280, Super S 27 m, 54 nozzles, 10 km/h
Permissible application rate
=
240 l/min - 0,05 x 1500 l
= 165 l/min
→
Application rate per nozzle = 3,1 l/min
→
Permissible application rate per hectare
= 372 l/ha
UF BAG0012.11 04.19
43
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......