![Amazone UF 1201 Operating Manual Download Page 142](http://html1.mh-extra.com/html/amazone/uf-1201/uf-1201_operating-manual_2919803142.webp)
Using the machine
11.2.1
Calculating the filling and re-fill quantity
To calculate the required re-fill quantity for final filling of the spray
liquid tank use the "Filling table for remaining spray area", Seite 143.9
Example 1:
The following are given:
Tank nominal volume
1,200 l
Residue in the tank
0 l
Water consumption
400 l/ha
Agent required per ha
Agent A
1.5 kg
Agent B
1.0 l
Question:
How many litres of water, how many kg of Agent A and how many
litres of Agent B must be used to treat a surface of 2.5 ha in area?
Answer:
Water:
400 l/ha
x
3 ha
= 1,200 l
Agent A
1.5 kg/ha
x
3 ha
= 4.5 kg
Agent B
1.0 l/ha
x
3 ha
= 3 l
Example 2:
The following are given:
Tank nominal volume
1,200 l
Residue in the tank
200 l
Water consumption
500 l/ha
Recommended concentration
0.15 %
Question 1:
How many litres or kg of agent are needed to fill the tank?
Question 2:
How large is the area to be treated in ha if a residue of 20 l remains in
the tank after spraying?
142
UF BAG0012.11 04.19
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...