![Amazone UF 1201 Operating Manual Download Page 169](http://html1.mh-extra.com/html/amazone/uf-1201/uf-1201_operating-manual_2919803169.webp)
Using the machine
11.9.9
Cleaning the sprayer with a full tank (work interruption)
•
If spraying operation is interrupted due to bad weather, clean the
suction filter, the pump, the valve chest and the spray line.
1. Switch off the sprayer boom.
2. Switch off agitator
C
.
3. Move switch tap
B
to the
position.
4. Move switch tap
A
to the
position.
5. Run the pump at pump operating speed
(at least 400 rpm).
6. Approx. 20 seconds after switching on the
pump, close the DUS tap (DUS option) to
avoid separation of the spray liquid.
7. Then spray the undiluted residue out of the
sprayer boom onto an
untreated
area.
8. Then spray the residue - which has been
diluted with water from the flushing water
tank - out of the suction filter, pump, valve
chest and spray line on to an
untreated
ar-
ea.
9. Dump the technical residue from the valve
chest into a suitable collection vessel; see
Seite
161.
10. Clean the suction filter; see Seite 165.
11. Switch off the pump drive.
12. Reopen the DUS tap.
Fig. 125
Continuing the spraying operation
Before continuing with the spraying operation, activate the pump for
five minutes at 540 min
-1
and switch on the agitators completely.
UF BAG0012.11 04.19
169
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......