Using the machine
11.9.3
Cleaning the suction filter
Clean the suction filter (Fig. 129) on a daily basis after spraying oper-
ation.
1. Undo the thumb screw (Fig. 129/1) on the
suction filter.
2. Remove the filter cup (Fig. 129/2) while
turning it gently left and right.
3. Pull out the filter insert (Fig. 129/3) and
clean with water.
4. Check the O-rings (Fig. 129/4) for damage.
5. Reassemble the suction filter in the reverse
sequence.
Fig. 121
Make sure that the O-rings (Fig. 129/4)
are correctly fitted.
11.9.4
Cleaning the suction filter when tank is full
1. Run the pump 300 U/min.
2. Move switch tap
D
to position
.
3. Move switch tap
E
to position
.
4. Move switch tap
A
to the
position
and dump the technical residue from the
valve chest and the suction hose into a
suitable collection vessel; see
Seite
164.
5. Undo the thumb screw (Fig. 130/1) on the
suction filter.
6. Remove the filter cup (Fig. 130/2) while
turning it gently left and right.
7. Pull out the filter insert (Fig. 130/3) and
clean with water.
8. Check the O-rings (Fig. 130/4) for dam-
age.
9. Reassemble the suction filter in the re-
verse sequence.
10. Move switch tap
E
to position
.
11. Check the suction filter for leak tightness.
Fig. 122
UF BAG0012.11 04.19
165
Summary of Contents for UF 1201
Page 19: ...General safety instructions Super S boom Fig 4 Q Plus boom Fig 5 UF BAG0012 11 04 19 19 ...
Page 204: ...Liquid circuit 14 Liquid circuit single nozzle control 204 UF BAG0012 11 04 19 ...
Page 205: ...Liquid circuit Part width section control UF BAG0012 11 04 19 205 ...
Page 210: ...Spray table Fig 157 210 UF BAG0012 11 04 19 ...
Page 219: ...Spray table UF BAG0012 11 04 19 219 ...
Page 220: ......