![Amazone Precea 4500-2 Original Operating Manual Download Page 142](http://html1.mh-extra.com/html/amazone/precea-4500-2/precea-4500-2_original-operating-manual_2919774142.webp)
D = Flow rate in l/min
A = Rate in kg/ha
v = Forward speed in km/h
R
W
= Row width in m
2.
Determine the flow rate with the equation.
D
A v
D
154
D
=
´ ´
=
´
´
=
=
´
´
=
R
W
600
15 0 75
600
2 89
600
.
,
CMS-I-00002733
Flow rate
Valve position
Pressure
1 bar
1.5 bar
2 bar
2.5 bar
3 bar
3.5 bar
4 bar
1
0.43 l/mi
n
0.53 l/min
0.61 l/min
0.68 l/min
0.74 l/min
0.8 l/min
0.86 l/min
2
0.61 l/mi
n
0.75 l/min
0.87 l/min
0.97 l/min
1.06 l/min
1.15 l/min
1.23 l/min
3
0.97 l/mi
n
1.19 l/min
1.37 l/min
1.53 l/min
1.68 l/min
1.81 l/min
1.94 l/min
4
1.4 l/min
1.71 l/min
1.98 l/min
2.21 l/min
2.42 l/min
2.62 l/min
2.8 l/min
5
2.15 l/mi
n
2.63 l/min
3.04 l/min
3.4 l/min
3.72 l/min
4.02 l/min
4.3 l/min
6
3.1 l/min
3.8 l/min
4.38 l/min
4.9 l/min
5.37 l/min
5.8 l/min
6.2 l/min
7
3.97 l/mi
n
4.87 l/min
5.62 l/min
6.28 l/min
6.88 l/min
7.43 l/min
7.95 l/min
8
5.06 l/mi
n
6.19 l/min
7.15 l/min
7.99 l/min
8.76 l/min
9.46 l/min
10.11 l/min
3.
Depending on the set pump pressure,
read the valve position from the table above.
4.
Move the valve
1
to the desired position.
5.
Since the flow rate depends on the applied
material,
check the setting by calibrating.
Observe the operating manual for the liquid
fertiliser tank
CMS-I-00002735
6 | Preparing the machine
Preparing the implement for operation
MG6149-EN-GB | J.1 | 18.10.2022 | © AMAZONE