4.Operation
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Maintenance timer setting
This instruction is for setting the timer that informs the inspection time of electrode and the product. The
default of timer is 2000 hours. Remove the electrode from the product over 1 time per 3 months and inspect
the product, collecting unit(eliminator
、
charging electrode
、
collecting electrode).Set the time due to the use
condition.
During operation, it is only displayed and the setting cannot be changed.
Be sure to stop the operation before setting.
●
1
Changing the mode setting
Press
△
or
▽
switch to make
⑦
appear in the top right
corner in the mode setting display.
●
2
Making flash the top-right icon “
⑦
”
Press the SET switch to blink
⑦
of the top right corner.
●
3
Changing the setting
During blinks of
⑦
, press
△
or
▽
switch to appear n-03 on the
display. Then, press the SET switch to appear
『
2000
』
in display.
After the setting, press the SET switch during “2000” blinking. At the
time of registration, the buzzer sounds.
Setting range
:
0
~
9000hours
Default
:
2000hours
This setting can be changed per 100 hours.
●
4
Back to the top
Press the ESC switch to back the display condition as suggested in the right.
・
Be sure to press the SET switch during blinks of the icons
in display. At the time of registration, the buzzer sounds and
the setting become effective. If you forget to press the SET
switch or the buzzer does not sound, the setting is not
changed.
・
If the maintenance timer setting is set
『
0
』
, the function of
maintenance timer becomes invalid.
・
If the setting time is reached to
『
0
』
, warning message of
maintenance displays, but the operation is continuing.
Caution