4
1
.
For safety operation
(continue)
Important
●
This mist collector can not be used for the following mists, because they may cause a fire or
accident:
・
Oil mist which contains combustible dust with explosively such as carbon, magnesium, and/or
aluminum powder.
・
Oil mist which contains a lot of dust(1
%
or more in weight ratio).
・
Oil mist whose ignition is likely.
・
Oil mist which may corrode this mist collector.
・
Oil mist which is of high viscosity and may adhere in the mist collector.
・
Oil mist which may adhere even in the allowable temperature range, 0 to 40
℃
)
・
Soluble mist which has over 300mS/m of the electric conductivity
・
Oil mist which has 200mg/m
3
of the maximum concentration
・
Oil mist which may pose adhesion due to the change of application conditions such as temperature,
moisture, and operation time.
Be sure to ground the mist collector.
If the equipment is not grounded, electrical leakage
occurs and there is a danger of fire or electric shock.
Also, the equipment could be damaged or
malfunction due to static electricity.
If fire or dust explosion occurs inside
the mist collector, immediately take the
following action.
・
Turn off the power supply immediately.
・
Use a fire extinguishing agent suitable for dust.
・
Even after the fire is out, never open the door until
the internal temperature drops to the normal level.
Otherwise, a secondary explosion could occur.
Perform periodic inspection written in
the operation manual.
Failure to do so could cause malfunction or fire.
When the mist collector stopped due to
power shutdown, be sure to check the
electrodes (charging electrodes, collecting
electrodes) and clean them.
Failure to do so could cause malfunction or fire.
Periodically clean the adhered or
deposited materials from inside the
main unit or pipes.
Failure to do so could cause fire.
Before you open the inspection door,
wait 20 seconds after you turned off the
power supply.
Failure to do so could cause electric shock.
Allow only person who is in charge of
maintenance to open the electrical
equipment cover.
Failure to do so could cause electric shock.
Be sure to turn off the power when
opening the inspection door or
electrical equipment cover.
Failure to do so could cause troubles, injury, electric
shock.
Never turn on the switch with the
inspection/electric part door opened.
Failure to do so could cause troubles, injury, electric
shock.
Never allow the machine to suck dust
such as soot or fume alone.
Failure to do so could cause fire.
Do the following maintenance.
・
Check the condition of contamination in year.
・
When contaminant is accumulated 2mm or thicker
on a part, clean the part.
・
In the case that even after the inspection and
cleaning, abnormal sparks take place frequently
and the mist collector stops by power shutdown,
clean the electrodes.
Failure to do so could cause abnormal sparks.
WARNING