47
6. Troubleshooting
Immediately after an error occurred during operation, stop the supply power for safety and inspect around. If the error has not been
cleared, do not attempt repair by yourself, Contact your dealer of Amano representative.
Condition
Problem
Cause
Corrective
action
Ref
Power is not being supplied to unit.
Check power supply source.
-
Disconnection of power cord
Check the broken part and repair or replace it.
-
Electric outage
Wait for power to resume.
-
Motor is broken down.
Replace the motor.
-
Inspection door is opened.
Close the inspection door correctly.
-
Unit will not start
even though ON
operation switch
has been pressed.
Set maintenance time is reached
(Only when the panel is operated.).
Check the electrode and cancel by reset switch.
-
Thermal relay has tripped due to drop
of power voltage.
Remove the cause of thermal relay trip and press
the reset switch.
P
.
32
Power failure
Make the power source stabilized.
-
Abnormal spark discharge or
short-circuit in charging electrode or
collecting electrode
When it caused by contamination, clean the
electrodes, or when it caused by deformation or
damage, replace them.
P
.
39
Fuse burnout
Replace the fuse to new one.
-
Unit stops suddenly
during operation.
Electric outage
Wait for power to resume.
-
F
an and mot
or is not st
arted.
Unit is not operated.
Power voltage is lacking of stability.
Make the power voltage stabilized.
-
Block on inlet duct
Eliminate the cause of blockage.
-
Improper duct diameter on inlet side
Change to an appropriate bore of suction duct.
-
Clogged eliminator
Clean the preceding filter or replace it.
P
.
39
Exhaust port is clogged.
Eliminate the cause of blockage.
-
Inadequately sealed duct on inlet side
Attach a metal piece to the connected portion of the duct.
-
Suction force is
weak.
Reverse rotation of motor
Check the rotation direction of motor.
P
.
16
Improper drainage
Improve the way to drain oil in order for a constant
draining of oil at all time.
P
.
12
Fault in collecting unit (contamination,
deformation, etc.)
Check the charging/collecting electrode and
eliminate the cause.
-
The concentration of suction mist is too
high.
Let in secondary air.
Add the preprocessing BOX.(option)
-
The collecting /charging electrode is dirty. Clean the charging/collecting electrode.
P
.
41
P
.
43
Set maintenance period has passed
Clean the charging/collecting electrode by immersing in
the cleaning liquid.
P
.
39
Leak or discharge
of mist
from the
exhaust port.
The oil is sucked directly.
Attach the baffle plate. Keep distance from the mist source.
P
.
13
The collecting /charging electrode is dirty. Clean the charging/collecting electrode.
P
.
41
P
.
43
Abnormal
discharge occur
such as spark
Fault in collecting unit (contamination,
deformation, etc.)
Check the charging/collecting electrode and
eliminate the cause.
-
Trouble in fan/motor
Check the install condition of fan/motor or failure. If
any, replace them.
-
F
an and mot
or is movin
g
There is abnormal
vibration, noise, or
smell
Ozone is generated from the electrode.
Lower the output of electrode or review the system of
ventilation.
-
●
During inspection, make sure to cut the power supply to unit for safety. Be sure to use the appropriate personal protective
clothes and equipments.
Caution