48
7. Periodic inspection
The frequency to check differs depending on the conditions to use the mist collector .The following
frequency of check is just a reference, but it is not a guaranteed value. The frequency of check may need to
be set earlier depending on the need.
Inspection period
Location to
inspect
Daily Weekly
Monthly
Relevant
standards
Inspection method and contents
Leak of mist
from exhaust
port, or mist
discharge
○
1. Check the collection unit.
2. Check for leak of mist from exhaust. If any leak
of mist,
check the status of oil drainage.
Hood
Ducts/hoses
Inside the mist
collector
○
1. Check the installation condition. If no good, install correctly.
2.Inspect for damage or deformation. If found,
repair or
replace.
3. Inspect for mist or dust accumulation inside
ducts/ Hoses or
hood. When a deposit is found
in the pipe, adjust the
position of the pipe to prevent such accumulation.
4. Wipe off the oil dropped around the main body with a cloth.
State of oil
drainage
○
1. Check that oil is being drained continuously.
2.Check for deterioration of hose and check the
connected portions.
Power code
terminal
○
1.Inspect power cords for deterioration, damage poor
installation. If covering is damaged and core wires are
exposed, stop using and replace.
2. When a power plug is used, check breakage and deformation of it.
3. Tighten screws of power cord or cable terminal in side of the
motor.
Feed plate
Feed spring
(charging/collectin
g electrode)
○
1. Check the degree of contamination and check for damage. If
contaminated, wipe it off. If damaged, contact Amano local office
or dealer for replacement.
2. Replace the charging/collecting electrode and check it over
once in 3 months regardless of the condition of
contamination. (Refer to the page
P
.
33
)
Power feed part
on the main
body side
○
1. Check the degree of contamination and check for damage. If
contaminated, wipe it off. If damaged, contact Amano local office
or dealer for replacement.
2. Check it over once in 3 months regardless of the condition of
contamination. (Refer to the page
P
.
33
)
Charging
electrode
○
1. Check the install condition. If any, install correctly
2. Check the degree of contamination and check for damage. If
contaminated, clean it off. If damaged, replace it.
3. Remove the charging/collecting electrode and check it over
once in 3 months regardless of the condition of
contamination. (Refer to the page
P
.
33
)
4. In the case of including mist in the exhaust air, clean it
regardless of the condition of contamination.
Collecting
electrode
○
When contaminant
is accumulated
2mm or thicker on
the electrodes.
In case of abnormal
sparks take place
frequently and the
mist collector stops
by power
shutdown, clean the
electrode.
1. Check the install condition. If any, , install correctly
2. Check the degree of contamination and check for damage. If
contaminated, clean it off and if damaged, replace it.
3.Remove the collecting electrode and check it over once in 3
months regardless of the condition of contamination. (Refer
to the page
P
.
33
)
Eliminator
○
1. Check the install condition. If any, install correctly
2. Check the degree of contamination and check for damage. If
contaminated, clean it off. If damaged, replace it.
3. Remove the eliminator and check it over once in 3 months
regardless of the condition of contamination. (Refer to the page
P
.
33
)
Motor
Motor needs inspection every 2-3 years. Contact Amano local office or dealer.
●
Follow all operation and maintenance instructions and carry out the daily and periodic inspections as
specified in this manual.
●
Observe all applicable laws and regulations regarding the installation and maintenance of the mist
collector.
●
During inspection, make sure to cut the power supply to unit for safety. Be sure to use the appropriate
personal protective clothes and equipments.
Caution