44
5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Cleaning of the collecting electrode
(continue)
●
6
Checking the condition of the feed spring
Dirt and contaminant on the power supply spring should be checked,
and if any, wiped away with dry waste or cloth. If the dirt is sticky and will
not be removed easily, use the waste or cloth impregnated with the wash
oil (of the type identical with the collected oil mist). The feed point on the
main unit is also provided with such insulator, which should be cleaned
likewise.
●
7
Checking the condition of the collecting
electrode
Before installing the cleaned collecting electrode back to the main unit,
check and ensure it is free from foreign substance on, deformation of,
or bends in the plates. The foreign substance on the plate would cause
abnormal
spark discharge.
●
8
Installing the collecting electrode.
Install the collecting electrode back to the main unit and close the
inspection door.
Feed
insulators
Feed
spring
If the contaminant is attached with
feed plate or feed plate, wipe it.