4.Operation
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Setting of continuous operation of Fan
Important
●
When the setting is available, the fan starts continuous operation. Press the STOP switch to stop the fan.
When this setting is enabled, only the high voltage output is stopped and fan is continuously operating. This setting
effect in the case of discharging mist continuously. This setting cannot be changed during operation.
Be sure to stop the operation before setting.
●
1
Changing the mode setting
Press
△
or
▽
switch to make
⑦
appear in the top right corner
in the mode setting display.
●
2
Making flash the top-right icon “
⑦
”
Press the SET switch to blink
⑦
of the top right corner.
●
3
Changing the setting
During blinks of
⑦
, press
△
or
▽
switch to appear n-02 on the
display. Then, press the SET switch to appear
『
000
』
in display. After
the setting, press the SET switch. At the time of registration, the
buzzer sounds.
000
・・・
Unset(default)
001
・・・
Set(The fan stops only in
case of high voltage)
●
4
Back to the top
Press the ESC switch to back the display condition as suggested in
the right.
Be sure to press the SET switch during blinks of the icons in
display. At the time of registration, the buzzer sounds and the
setting become effective. If you forget to press the SET switch
or the buzzer does not sound, the setting is not changed.
Caution