15
3
.
Preparation
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Connecting to the power supply
Important
●
All electrical wiring work must be performed by a competent electrician.
●
1
Checking the specifications of the power
Check the name plate that the power specifications of the
product is suit with the power outlet.
●
2
Turning off the switch.
Be sure to turn off the current breaker for preventing electric
shock.
●
3
Grounding the earth
Ensure that the earth is installed in accordance with the
requirements that mean maximum grounding resistance is 100
ohms and under.
●
4
Connecting wires except the earth
Screw the power cord except the earth firmly with the terminal
block of the electric breaker.
●
5
Turning on the switch
Check the above
①
to
④
again and turn on the switch of the electric breaker.
Checking of the breaker
:
For safety, install the breaker on the side of the primary power source. The recommended trip value of the breaker
is the following in chart.
Model
Type of breaker
Trip value(Power 200
V
)
EM
-
15e
Ⅱ
10A
EM
-
30e
Ⅱ
MCB(Electric breaker for wiring)
or
ELB(Earth leakage circuit breaker )
15A
Earth
Circuit
breaker
Switchboard
Power cord