12. Timing Chart (2-axis Type)
12-11
(5) Sample Hold 3 Mode “Disp Measure Mode : SH3(4)”
When 0=Setup parameter of the function menu is set as follows:
1
Disp Measure Mode setting: SH3(4)
3ms
2ms
1ms
18ms
2ms
20ms max.
1ms
2ms
(*1)
(*4)
20ms min.
LEV-DISP1 set displacement
After Weld Work
measurement position
LEV-DISP2 set displacement
GOOD output(*2)
FINISH output(*2)
NG output(*2)
After Weld Work measurement
Displacement measurement
Displacement change 1
Before Weld Work measurement
ST-DISP2 input
LEV-DISP11 to 13 output
LEV-DISP21 to 23 output
(*3)
(*3)
Before Weld Work measurement position
1st
2nd
20ms min.
Displacement change 2
ST-DISP1 input
20ms min.
1st
2nd
20ms min.
*1 Time from when both ST-DISP1 and 2 (second time) are input.
*2 The output time can be selected with Output Select Time.
*3 The output time can be selected with Level Select Time.
*4 When NG is output, the sequence ends.