MU-100A
8. Function Setting
8-8
(3) Selecting Items Displayed on LCD (1=Monitor
Display)
Selects the monitored values displayed on the normal screen.
For 2-axis type, first axis (Axis1) and second axis (Axis2) can be selected
respectively.
a. Parameter item
Item
Selections
Remarks
Symbol
Description
Initial value
Selections
MD11
Monitor Display11
Before Force(0) Before Force(0)
After Force(1)
Now Force(2)
Before Work(3)
After Work(4)
Displacement(5)
Now Work(6)
Counter(7)
First axis
MD12
Monitor Display12
After Force(1)
MD13
Monitor Display13
Now Force(2)
MD14
Monitor Display14
Before Work(3)
MD15
Monitor Display15
After Work(4)
MD16
Monitor Display16
Displacement(5)
MD17
Monitor Display17
Now Work(6)
MD18
Monitor Display18
Counter(7)
MD21
Monitor Display21
Before Force(0)
Second axis
MD22
Monitor Display22
After Force(1)
MD23
Monitor Display23
Now Force(2)
MD24
Monitor Display24
Before Work(3)
MD25
Monitor Display25
After Work(4)
MD26
Monitor Display26
Displacement(5)
MD27
Monitor Display27
Now Work(6)
MD28
Monitor Display28
Counter(7)
b. Selections
Before Force(0): Before-welding force value
After Force(1):
After-welding force value
Now Force(2):
Present force value
Before Work(3): Before-welding workpiece thickness
After Work(4):
After-welding workpiece thickness
Displacement(5): Displacement
Now Work(6):
Present workpiece thickness
Counter(7):
Counter value