MU-100A
6. Interface
6-3
c. OUTPUT1 connector: KF22X-B37S-NJM(KYCON)
* For SENSOR1 and 2
* Use the shielded cable for the output cable and connect the shielded part to the ground.
No
Symbol Contents
1 READY1
Device normal signal. Turned OFF while the setting screen is displayed.
2 GOOD-DISP1
The GOOD signal of displacement sensor when the Disp Measure Mode for
SENSOR1 and 2 is set to SYNC, SQNC, or SH1,2,3. When it is set to SYNC,
this is the GOOD signal common to the displacement sensor and the load
cell.
3 GOOD-FORCE1
The GOOD signal of load cell when the Force Measure Mode for SENSOR2
is set to SQNC, SH1/2, or TANG. Do not use when the Disp Measure Mode is
set to SYNC.
4 NG1
Output when the measured value for SENSOR1 and 2 is outside the
upper/lower limit.
5 NG-UP1
Output when the measured value of the displacement sensor for SENSOR3
exceeds the upper limit.
6 NG-LO1
Output when the measured value of the displacement sensor for SENSOR3
falls below the lower limit.
7 NG-BEFORE1
Output when the before-welding workpiece thickness for SENSOR3 is NG.
8 NG-DISP1
Output when the displacement for SENSOR3 is NG.
9 NG-AFTER1
Output when the after-welding workpiece thickness for SENSOR3 is NG.
10 NG-FORCEUP1
Output when the measured value of the load cell for SENSOR4 exceeds the
upper limit.
11 NG-FORCELO1
Output when the measured value of the load cell for SENSOR4 falls below
the lower limit.
12 WARNING
Output when an ERROR occurs. (See
16. Troubleshooting
.)
13 WELD
START1
The start signal for welding power supply for SENSOR1 and 2.
Output for the time set in Weld-Time.
14 FINISH1
Output when the sequence operation for SENSOR1 and 2 ends.
15 LEV-DISP11
16 LEV-DISP12
17 LEV-DISP13
Output when the present value of the displacement sensor for SENSOR1
passes the setting.
18 LEV-FORCE11
19 LEV-FORCE12
20 LEV-FORCE13
Output when the present value of the load cell for SENSOR2 passes the
setting.
21 OUTPUT11
22 OUTPUT12
23 OUTPUT13
24 OUTPUT14
25 OUTPUT15
26 OUTPUT16
Spare output signals.
27 SVCOM1
Common for the solenoid valve control signal for SENSOR1 and 2.
28 SV11
The solenoid valve control signal for SENSOR1 and 2.
29 SV12
30 SV13
Spare solenoid valve control signal.
31 V-SIG11
Converts the present value of the displacement sensor for SENSOR1 to
voltage to output it. *1
32 V-SIG12
Converts the present value of the load cell for SENSOR2 to voltage to output
it. *2
33 V-SIGCOM1
Common for voltage output for SENSOR1 and 2.
34 OUTCOM
35 OUTCOM
36 OUTCOM
37 OUTCOM
Common for output signals for SENSOR1 and 2.