1. Special Precautions
1-2
Do not insert your fingers or hands between the electrodes.
When welding, keep your fingers and hands away from the electrodes.
Do not touch any welded part or electrode during welding or just after
completion of welding.
The welded parts of a workpiece, electrodes, and the arm are very hot.
Do not touch them; burns may result.
Ground the equipment.
If the Controller is not grounded, you may receive an electric shock in the
event of malfunction or current leak.
!
Connect the specified cables securely.
Cables of insufficient current capacities and loose connections can cause
fire and electric shock.
Do not damage the power cable and connecting cables.
Do not tread on, twist, or apply force to any cable. Doing so may cause the
power cable and connecting cables to become broken, leading to electric
shock and fire.
Do not use any damaged power cable, connecting cable, or plug.
Failure to observe this precaution can lead to electric shock, short circuit, or
fire.
If any part must be replaced or requires repair, consult us or your distributor.
!
Stop the operation if any trouble occurs.
Continuous operation after occurrence of a trouble such as burning smell,
abnormal sound, abnormal heat, smoke, etc. can cause electric shock and
fire.
If such a trouble occurs, immediately consult us or your distributor.
!
Persons with pacemakers must stay clear of the welding machine.
A person who uses a pacemaker must not approach the welding machine or
walk around the welding site while the welding machine is in operation,
without being permitted by his/her doctor. The welding machine generates a
magnetic field and has effects on the operation of the pacemaker while it is
turned on.
!
Protective gear must be worn.
Put on protective gear such as protective gloves, long-sleeve jacket, leather
apron, etc. Surface flash and expulsion can burn the skin if they touch the
skin.
!
Wear protective glasses.
If you look at the flash directly during welding, your eyes may be damaged.
If any surface flash and expulsion gets in your eye, you may lose your
eyesight.
WARNING
!