MU-100A
10. Setting of Measurement Mode and Schedule
10-11
b. Setting of measurement schedule
1
Press MONI key to display the normal screen.
2
Press SCH key to select “SCH Axis”.
3
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis) to set the schedule number.
4
Set No.1 “Squeeze-Time”, No.2 “Weld-Time”, and No.3 “Hold-Time” to the time
same as the set time for the welding power supply. When “LS Input Validity”
(force-detecting signal input) is set to “Valid(0)”, “Squeeze-Time” setting is
unnecessary.
5
Set the monitoring level according to your use conditions.
Monitoring of the before-welding force
No.10 “Before Weld Force LO” (before-welding force lower limit)
No.11 “Before Weld Force UP” (before-welding force upper limit)
Monitoring of the after-welding force
No.12 “After Weld Force LO” (after-welding force lower limit)
No.13 “After Weld Force UP” (after-welding force upper limit)
6
Set the level output according to your use conditions.
Use of Force level output
No.17 “Force Level1”
No.18 “Force Level2”
No.19 “Force Level3”
c. Measurement
1
Press MONI key to display the normal screen.
2
Set the schedule by selecting schedule switching signals “SCH1”, “SCH2”,
“SCH4”, “SCH8”, “SCH16”, “SCH32”, and “SCH64” or via the panel.
3
Input “ST-FORCE1” or “ST-FORCE2” (second axis) to make a measurement.