MU-100A
14. Specifications
14-1
14.
Specifications
(1) Basic Specifications
Item
Contents
Power supply voltage
Single-phase, 100 to 240 V AC±10% (50/60
Hz), 0.5 A
Fuse rating
250V1A
Operating environment
Temperature 5 to 40°C, Humidity 90% or less
Storage environment
0 to 55°C
Outline dimensions
109 (H) × 200 (W) × 268 (D) mm
(not including projection)
Mass
3.3 kg
Control mode
Displacement Load cell SYNC
Displacement sensor
SQNC, SH1, SH2, SH3
Load cell
SQNC, SH1, SH2, TANG
Time setting
Squeeze time, Weld time, Hold time
Time setting range
0 to 9.999 sec
Number of schedules
127
Counter
Start counter, Preset counter
Communication
Ethernet, RS-232C, RS-485
Displacement
sensor
Applicable sensor
Incremental type
Measurement range
0 to ±50.000 mm
Upper/lower limit setting range
0 to ±99.999 mm
Resolution
1
μm
Measurement item
Before-welding workpiece thickness,
After-welding workpiece thickness,
Displacement
Level outputs
3
Analog output
1 (output delay time: approx. 1.5 ms)
Origin setting
Valid
Accuracy
30-mm displacement sensor or shorter:
±0.015 mm (*)
50-mm displacement sensor: ±0.025 mm (*)
Load cell
Measurement range, Resolution
1.00 to 20.00 N, 2.50 to 50.00 N:
0.01N increments
10.0 to 200.0 N, 25.0 to 500.0 N:
0.1N increments
100 to 2000 N, 250 to 5000 N: 1N increment
500 to 10000 N: 10N increments
Upper/lower limit setting range
0 to 20.00 N, 0 to 50.00 N: 0.01N increments
0 to 200.0 N, 0 to 500.0 N: 0.1N increments
0 to 2000 N, 0 to 5000 N: 1N increment
0 to 10000 N: 10N increments
Applicable rated output
0 to 2 mV/V
Measurement item
Before-welding force, After-welding force
Level outputs
3
Analog output
1 (The output delay time varies according to
the Force Sampling setting.)
Zero setting
Valid
Accuracy
Full scale±3% (*)
* When using the sensor purchased from us.