(3) Sample Hold 1 Mode “Disp Measure Mode : SH1(2)”
This is the mode for measuring displacement. The workpiece thickness can be
measured and judged at the input of “ST-DISP1” or “ST-DISP2” (second axis).
(The workpiece thickness can be measured and checked at a given point in time.)
a. Setting of measurement mode
1
Press FUN, 0 and ENT keys in this order to select “0=Setup”.
2
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis).
3
Set No.3 “Disp Measure Mode” (measurement mode of displacement sensor) to
“SH1(2)” (sample hold 1 mode).
4
When not using the load cell, set No.8 “Force Measure Mode” (measurement
mode of load cell) to “OFF(4)” (load cell off mode).
b. Setting of measurement schedule
1
Press MONI key to display the normal screen.
2
Press SCH key to select “SCH Axis”.
3
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis) to set the schedule number.
4
Set the monitoring level according to your use conditions.
Monitoring of the before-welding workpiece thickness
No.4 “Before Weld Work LO” (before-welding workpiece thickness lower limit)
No.5 “Before Weld Work UP” (before-welding workpiece thickness upper limit)
c. Measurement
1
Press MONI key to display the normal screen.
2
Set the schedule by selecting schedule switching signals “SCH1”, “SCH2”,
“SCH4”, “SCH8”, “SCH16”, “SCH32”, and “SCH64” or via the panel.
3
Input “ST-DISP1” or “ST-DISP2” (second axis) to make a measurement.
WORK value
ST-DISP
Monitor judgment with upper/lower
limit value of Before Weld Work only
Can be measured
at any given point.
WELD
value
WORK
value
WELD
value
WORK
value
Before
welding
After
welding