MAWA-300B
4. Explanation of Screens
4-36
(14) External I/O Check Screen
This screen is used to check the external input/output signal status.
In the case of an ON signal, the terminal No. portion lights. When the signal is OFF, the display
lamp goes out. The input/output status screen is classified into the “I/O check” screen and the “I/O
check (option)” screen.
1
I/O check screen
(a) Input state
The input signal status is displayed.
Terminal 1
W.STOP
Terminal 9
SCH64
Terminal 2
START
Terminal 10 PARITY
Terminal 3
SCH1
Terminal 11
PURGE
Terminal 4
SCH2
Terminal 12 RESET
Terminal 5
SCH4
Terminal 13 EM.RESET
Terminal 6
SCH8
Terminal 20 ---
Terminal 7
SCH16
Terminal 21 WELD ON
Terminal 8
SCH32
Terminal 22 IN1
Terminal
23 IN2
(b) Output state
The output terminal status is displayed.
Terminal 1
GOOD
Terminal 9
OUT3
Terminal 2
NG
Terminal 10 OUT2
Terminal 3
END
Terminal 11
OUT1
Terminal 4
E.STOP
Terminal 12 SYNC
Terminal 5
ERROR
Terminal 15 OUT7
Terminal 6
OUT5
Terminal 16 OUT6
Terminal 7
OUT4
Terminal 17 WIRES