MAWA-300B
4. Explanation of Screens
4-39
(15) Count Setting Screen
This screen is used to control and check the number of welding times and the amount of production.
Each count value can be set and checked for each number.
(a) SCH
The condition No. being set is displayed.
(b) Preset count/Total count
Enabled when a value is input in “Preset.” The value inc1 each at
execution of welding is displayed in “Total count.”
(The setting range is 0 ~ 999999 [Initial value: 0]. Disabled when “0” is set.)
When enabled, this count is performed regardless of the welding result.
When “Preset” < “Total count”, “E19 TORCH.1 COUNT ERROR” / “E20 TORCH.2
COUNT ERROR” occurs. When an error occurs, a count error will occur again at
the following welding until the count value is reset.
(c) Work count preset/Work count
Enabled when a value is input in “Work count preset.” When “Weld count” value is
equal to “WELD count preset” value, the count is inc1 and is displayed as
“Work count.”
(The setting range is 0 ~ 60000 [Initial value: 0]. Disabled when “0” is set.)
* When the “Weld count” is disabled, this count is not performed.
When Work count preset” < “Work count”, “E19 TORCH.1 COUNT ERROR” / “E20
TORCH.2 COUNT ERROR” will occur. When an error occurs, a count error will
occur again at the following welding until the count value is reset.
(d) WELD count preset/Weld count
Enabled when a value is input in “WELD count preset”. The value inc1
each at execution of welding is displayed in “Weld count.”
(The setting range is 0 ~ 255 [Initial value: 0]. Disabled when “0” is set.)
When the “Weld count” value reaches the “WELD count preset” value, the “Work
count” value is inc1 and the “Weld count” value is reset.
(e) RESET
Used to reset each count value of “Total count”, “Work count” and “Weld count.”