MAWA-300B
6. Timing Chart
6-5
(5)
Touch Start (at occurrence of LOST)
The following is a timing chart for the case where the arc stops in the process of welding.
トーチヘッド 始点
移動動作
溶接点(本通電)
溶接点(初期電流)
初期電流開始入力
本通電開始入力
ガス開始入力
H-END出力
READY出力
出力
ガス出力
H-ST1
H-ST2
SYNC OUT出力
PURGE
LOST出力
溶接電流
WIRE START
END出力
NG出力
※5
出力
1~200ms ※4
約5ms
アーク切れ
※2
1~200ms ※3
設定時間
初期電流
1~200ms ※3
1~200ms ※1
設定時間
プリフロー
1~200ms ※3
H-HEAD UP
*1 Set value of “START signal input decided delay time.” Refer to “4. (6) Switch Select Screen.”
*2 Welding data creating time (approx. 60 ms for the first condition change or approx. 30 ms for the second or later change).
Refer to “4. (6) Switch Select Screen.”
*3 Set value of “END signal output time.” Refer to “4. (6) Switch Select Screen.”
*4 Set value of “GOOD/NG signal output time.” Refer to “4. (6) Switch Select Screen.”
*5 The LOST signal is turned on concurrently with the ON timing of the END signal. The output is kept, and when the H-ST1
signal is received and welding is started, this signal is turned off.
Torch head start point
Moving operation
Weld point (main welding)
Weld point (initial current)
H-ST1
Initial current start input
H-ST2
Main welding start input
PURGE
Gas start input
H-HEAD UP output
H-END output
PURGE gas flow
start output
READY output
SYNC OUT output
Welding current
WIRE START
output
END output
NG output
LOST output (*5)
Initial current
set time
Pre-flow
set time
Arc stop
Approx. 5 ms