MAWA-300B
2. Installation and Connections
2-29
Terminal name
Explanation
18.WEL2 UPPER
CURRENT
When the measured current waveform of the second welding exceeds the
upper limit of the judgment current value, this signal is output for the 02. NG
signal setting time.
19.WEL2 LOWER
VOLTAGE
When the measured voltage value of the second welding is lower than the
lower limit of the judgment voltage value, this signal is output for the 02. NG
signal setting time.
20.WEL2 UPPER
VOLTAGE
When the measured voltage value of the second welding exceeds the lower
limit of the judgment voltage value, this signal is output for the 02. NG signal
setting time.
21.WEL2 LOWER
TIME
When the second welding is lower than the lower limit of the judgment time, this
signal is output for the 02. NG signal setting time.
22.WEL2 UPPER
TIME
When the second welding exceeds the upper limit of the judgment time, this
signal is output for the 02. NG signal setting time.
23.WEL2 LOWER
ENVELOPE CUR
When the measured current waveform of the second welding is lower than the
lower limit of the judgment current waveform, this signal is output for the 02.
NG signal setting time.
24.WEL2 UPPER
ENVELOPE CUR
When the measured current waveform of the second welding exceeds the
upper limit of the judgment current waveform, this signal is output for the 02.
NG signal setting time.
25.WEL2 LOWER
ENVELOPE VLT
When the measured voltage waveform of the second welding is lower than the
lower limit of the judgment voltage waveform, this signal is output for the 02.
NG signal setting time.
26.WEL2 UPPER
ENVELOPE VLT
When the measured current waveform of the second welding exceeds the
upper limit of the judgment current waveform, this signal is output for the 02.
NG signal setting time.
27.SYNC. OUT
This signal is output in the period from the pre-flow output to the end of the
welding.
28.WIRE START
The brazing wire fed signal is output concurrently with a start of the main
welding.
29.TORCH SHORT
This signal is output with error display when the welding starts with the
torch and workpiece contacted and the output is kept up to the next welding
ON time.