MAWA-300B
4. Explanation of Screens
4-45
Screen Parameter
Initial
value
Monitor value measuring range
WELD1+WELD2
Slope time
Exclude
Current value
OFF
Voltage value
OFF
Weld time
OFF
Monitor select
screen (all of
condition Nos.
1 ~ 127)
Upper/lower limit judgment
output
Envelope OFF
WELD1 360
[A]
Upper limit
value
WELD2 360
[A]
WELD1 0
[A]
Current value
Lower limit
value
WELD2 0
[A]
WELD1 50.00
[V]
Upper limit
value
WELD2 50.00
[V]
WELD1 0.00
[V]
Voltage value
Lower limit
value
WELD2 0.00
[V]
WELD1 5000
[ms]
Upper limit
value
WELD2 5000
[ms]
WELD1 0
[ms]
Upper/lower
limit set screen
(all of condition
Nos. 1 ~ 127)
Time
Lower limit
value
WELD2 0
[ms]
Password
setting screen
Password
0
(No password setting)
Preset 0
Work count preset
0
WELD count preset
0
Total count
0
Work count
0
Count setting
screen
TORCH1
Weld count
0
*1: Touch start only
*2: High-voltage start only