MAWA-300B
4. Explanation of Screens
4-14
However, the reference voltage waveform is only “Mes Value.”
(t) Env Wave regist
Resistance welding is performed on the Envelope waveform check screen (Refer to
“4. (4)
1
Envelope waveform check screen.”) and “Record” is pressed in the status
where the envelope waveform is created, the envelope waveform data is saved into
the condition No. parameter being set.
(u) Envelope waveform registration status display
It is displayed that the envelope waveform is registered in the condition No. being set.
After “Record” is pressed and the waveform is successfully saved, “OK” is displayed.
When it is unsuccessful, “NG” is displayed. If the waveform is not saved, “NON” is
displayed.
(v) BACK
The Envelope waveform check screen is displayed.
(w) Monitor select
The Monitor select screen is displayed.
Waveform registration
status display