MAWA-300B
7. External Communication Function
7-7
(5)
Data Code Table
1
-1 Command 01 (condition data) Data for each condition No. (Condition No.: 001 ~ 127)
[Touch start setting]
Item Contents
Character
string
Range
1
Torch No.
nn,
01: TORCH 1
2
Condition setting mode
nn,
01: FULL setting mode
02: SIMPLE setting mode
3
Initial current value
4
WELD1 up-slope initial current
5
WELD1 up-slope final current
6
WELD1 main welding current
7
WELD1 down-slope initial current
8
WELD1 down-slope final current
9
Cooling in-process current value
10
WELD2 up-slope initial current
11
WELD2 up-slope final current
12
WELD2 main welding current
13
WELD2 down-slope initial current
14
WELD2 down-slope final current
nnn,
015 ~ 300 (A) (in unit of 1 A)
15
Pre-flow time
nnnn,
0000 ~ 9999 (ms)
16
Initial current time
nnn,
000 ~ 999 (ms)
17
WELD1 up-slope time
18
WELD1 main welding time
19
WELD1 down-slope time
nnn.n,
000.0 ~ 099.9 (ms) (in units of 0.1 ms)
100.0 ~ 999.0 (ms) (in unit of 1.0 ms)
20
Cooling time
nnnn,
0000 ~ 1000 (ms)
21
WELD2 up-slope time
22
WELD2 main welding time
23
WELD2 down-slope time
nnn.n,
000.0 ~ 099.9 (ms) (in units of 0.1 ms)
100.0 ~ 999.0 (ms) (in unit of 1.0 ms)
24
After-flow time
nnnn,
0000 ~ 9999 (ms)
25
WELD1 pulse modulation ON/OFF
n,
0: OFF 1: ON
26
WELD1 modulation frequency
nnnn,
0001 ~ 3000 (Hz)
27
WELD1 modulation duty ratio
nnn,
10 ~ 90 (%)
28
WELD1 slope section modulation
ON/OFF
n, 0:
OFF
1:
ON
29
WELD1 base current value
nnn,
015 ~ 300 (A) (in unit of 1 A)
30
WELD2 pulse modulation ON/OFF
n,
0: OFF 1: ON
31
WELD2 modulation frequency
nnnn,
0001 ~ 3000 (Hz)