CHAPTER 5: PROGRAMMING MODES
2 KHZ INVERTER WEDLING POWER SUPPLY
5-2
990-057
Basic Weld Monitor Run State
When
MENU, OPTIONS 1, WELD MONITOR:
is set
to
BASIC
, pressing
CHNG
will cause the display
screen to switch from the Weld Graph
RUN
screen
to the Basic Weld Monitor
RUN
screen. Setting
WELD MONITOR
to
LIMIT
causes the Energy Limit
Monitor screen to be displayed. See
Chapter 7
and
Chapter 8
for detailed instructions.
Pressing
CHNG
again causes the Basic Weld Monitor
RUN
screen to switch to the Alphanumeric RUN
screen. Pressing
CHNG
once more returns the display screen to the Weld Graph
RUN
screen.
Alphanumeric RUN State
Pressing
CHNG
will cause the display screen to
change from the Basic Weld Monitor
RUN
screen,
if this option has been set to
ON
, to the
Alphanumeric
RUN
screen. Pressing
CHNG
again
will return the Power Supply to the
Weld Graph
screen. Welding can be performed in any
RUN
screen.
NO WELD State
Switching the
WELD/NO WELD
front panel switch
to the
NO WELD
position prevents weld current
from flowing but does permit the Power Supply to
perform its electronic functions. Use the
NO
WELD
State when adjusting the air regulators on
Air Actuated Weld Heads.
STANDBY State
The Power Supply is waiting for a mandatory
event to occur such as: (a) the Firing Switch in an
AMADA WELD TECH Air Actuated Weld Head
to close; (b) the second level of a 2-Level Foot
Switch to close; or (c) waiting to be reset to
another schedule after a
STOP
Command in a
Chained Schedule.