CHAPTER 3: WELDING SYSTEM SET-UP
2 KHZ INVERTER WEDLING POWER SUPPLY
3-12
990-057
18
Press
ENTER
to complete the schedule
copy process and to automatically return
to the Weld Graph
RUN
State.
19
Press
PROGRAM
twice
to select the
Alphanumeric
PROGRAM
screen.
20
Press the down vertical cursor key
until the
RELAY 1: NOT USED
and
RELAY 2: OFF
option items appear.
21
Select
RELAY 1: NOT USED
. Press
CHNG
to select the
AIR HEAD 2
option.
22
Press
SAVE
to update Schedule 2, then
press
CHNG
to automatically return to
the Weld Graph
RUN
State. You are now
ready to adjust the Right Weld Head Air
Regulators.
23
Turn both Air Regulators located on the
right-hand side of the Right Weld Head
Clockwise (CW) to produce 10 psi on the
Pressure Gauge.
24
Press and hold the Foot Switch
completely down to close all switch
levels. The lower right hand corner of
the display should show the status
message
STANDBY
.