![Amada HF2 Operation Manual Download Page 48](http://html1.mh-extra.com/html/amada/hf2/hf2_operation-manual_2915802048.webp)
CHAPTER 4: CONTROLS
2 KHZ INVERTER WEDLING POWER SUPPLY
4-4
990-057
Sensing Port - Connector Pin Assignments
Pin No.
Wire Color
Description
1
Red
Secondary Weld Current Measurement
2
Red
+12 VDC
3
Red
Secondary Weld Voltage Measurement
4
Red
Weld Transformer Select Line 2 (For MA-600)
5
Red
Weld Transformer Thermo Switch
6
Red
Weld Transformer Select Line 4 (For MA-600)
7
Red
Digital Signal Ground
8
Black
230 VAC Weld Transformer Fan
9
Black
Secondary Weld Current Measurement Return
10
Black
Weld Transformer Select Line 1 (For MA-600)
11
Black
Secondary Weld Voltage Measurement Return
12
Black
Weld Transformer Select Line 3 (For MA-600)
13
Black
Weld Transformer Thermo Switch Return
14
Black
Future Expansion
15
Red
Future Expansion
16
Red
230 VAC Weld Transformer Fan Return
OUTPUT
The Output Cable feeds high voltage, pulse width modulated, primary weld current to the primary winding
of the Transformer. The connector attached to the end of the Output Cable is a TE Connectivity 206136-
1 (AWTA Part # 520-115). The mating connector on the Transformer is a TE Connectivity 206137-1
(AWTA Part # 550-071).
Pin No.
Wire Color
Description
1
Black
Primary HF2 Weld Transformer
2
Red
Primary HF2 Weld Transformer
4
Green
Chassis Ground
6
White
Primary HF2 Weld Transformer Return
7
Orange
Primary HF2 Weld Transformer Return