![Amada HF2 Operation Manual Download Page 39](http://html1.mh-extra.com/html/amada/hf2/hf2_operation-manual_2915802039.webp)
CHAPTER 3: WELDING SYSTEM SET-UP
2 KHZ INVERTER WEDLING POWER SUPPLY
990-057
3-15
11
Press
PROGRAM
twice to select the
Alphanumeric
PROGRAM
screen for
Schedule 2.
12
Verify that
NEXT: 001
is correctly
displayed so that Schedule 2 will
automatically advance to Schedule 1
after one weld has been completed. If
you want to make more than one weld
using Schedule 2 before advancing to
Schedule 1, change
STEP : 00001
to the desired number of welds.
13
Press
SAVE
to save the updated Schedule 2.
14
Press
▼
to select
SCH:001 BASIC WELD
.
15
Press
PROGRAM
once to select the Alphanumeric
PROGRAM
screen for Schedule 1.
Select
NEXT: 001
. Change
001
to
002
so that
Schedule 1 will automatically advance to
Schedule 2 after one weld has been completed. If
you want to make more than one weld using
Schedule 1 before advancing to Schedule 2,
change
STEP: 00001
to the desired number of
welds.
Press SAVE to save the uploaded Schedule 1.
Press CHNG to return to the Weld Graph RUN State. You are now ready to make alternating welds,
beginning with Schedule 1, by just pressing on the Foot Switch to activate each weld.