AC101
Preliminary Data Sheet
06/04/01
B r o a d c o m
Page 42
Digital Timing Characteristics
Document AC101-DS01-405-R¥¥¥¥¥
Figure 9:
100BASE-TX/FX MII Receive Timing
10BASE-T MII T
RANSMIT
S
YSTEM
T
IMING
RXD[3:0], RX_DV,
RX_ER Hold
tRXH
From rising edge of RX_CLK
10
-
-
ns
Table 43:
10BASE-T MII Transmit System Timing
Parameter
SYM
Conditions
Min
Typ
Max
Units
TX_CLK period
tCK
399.98
400.00
400.02
ns
TX_CLK High period
tCKH
180.00
200.00
220.00
ns
TX_CLK Low period
tCKL
180.00
200.00
220.00
ns
TX_EN to SOP
tTJ
240
-
360
ns
TX_EN sampled to
CRS
tTCSA
RPTR is logic low
-
-
130
ns
Table 42:
100BASE-TX/FX MII Receive System Timing (Cont.)
Parameter
SYM
Conditions
Min
Typ
Max
Units
FXRP/N
RX_CLK
RX_DV
RXD[3:0]
RX_ER
RX_DV
RXIP/N
/J/K
/T/R
tCK
tCKH
tCKL
tRXS
tRXH
tRDVA
CRS
COL
tRCSA
tRCSD
tRCLA
tRCLD
Start of Packet
End of Packet
tRDVD